Header and Utility Actions
The header shows the node display name, current status, application count, and uptime when available. The utility actions include:
The console hides actions your role cannot perform, rather than showing them in a disabled state. If you expect an action but do not see it, verify your role and project access.
Status Ribbon
Below the header, six cells provide an at-a-glance snapshot of the node without opening any tab.
Admin state appears in the ribbon as a secondary indicator under Status. For the full Admin state field with copy controls, see the Details tab under State & Timeline.
Overview Tab
Use Overview for a fast operational read. It includes workload previews for Applications, Virtual Networks, Volumes, and Patch Envelopes, a recent activity feed, the Live status panel, and the System and Security panel.Live status panel
The Live status panel shows real-time data reported by EVE-OS and read-only service settings for the node. It has the following sub-tabs: Resources, NTP info, Certificates, Edge Sync, and Edge View. The Edge View sub-tab appears only when Edge View is allowed for the node. Resources shows current utilization for the node’s CPU, memory, and storage, and the ratio of active uplink interfaces to total uplinks. Each metric includes a live value alongside a one-hour sparkline and average so you can distinguish a momentary spike from sustained load. CPU and memory figures show both allocated capacity (reserved for running application instances) and actual usage. A View Reports link opens the node on the Performance tab of the Reports page for deeper telemetry. See Reports. NTP info lists the NTP sources EVE-OS is using to synchronize the system clock. Each row shows the server address, stratum, mode (Client, Peer, or Reference), state (Sync, Candidate, Unreachable, and others), reachability, offset, and round-trip delay. The source currently disciplining the clock is marked as Sync. If no source is in Sync state, the system clock might drift. Certificates lists the certificates enrolled on the node for port-based network access control (802.1X). Each entry shows the subject common name, issuer common name, enrollment profile, status (Active, Pending, Renewing, Expired, Revoked, or Failed), and expiration date. If no certificates are enrolled, the panel notes that port-based NAC is configured at the project level. See Configure 802.1X with SCEP for enrollment setup. Edge Sync is a read-only summary of the node’s Edge Synchronization settings. It always appears, whether or not Edge Sync is configured, because knowing that a node has Edge Sync turned off is also useful. It shows the following:- Local orchestration: Enabled or Disabled. The node counts as enabled only when it has an Edge Sync URL set. When it is not set, the sub-tab notes that Edge Sync is not configured for this node.
- Edge Sync URL: the address of the Edge Sync server this node falls back to. The row shows a dash when no URL is set.
- Data Stores: the names of the datastores attached to the node’s Edge Sync configuration. The row shows Not Configured when no datastore is attached.
System and Security panel
The System and Security panel summarizes the node’s security posture. It shows individual signals for attestation, HSM, PCR, virtualization, ECC memory, Configuration Lock, and Edge Sync when the node reports them. Hover over a signal to open a card with more detail. You can collapse the panel when you do not need it. Hovering the PCR signal opens a card that lists the node’s reported PCR values, along with the EVE-OS (Edge Virtualization Engine) image version and firmware version reported at the last attestation. Select Copy All to copy every PCR index and value, or use the copy icon on a row to copy a single value. The footer of the PCR card links to the PCR template for the node’s hardware model, in one of two forms:- If the node’s reported PCR values already match a template on the hardware model, the footer shows the template name. Select it to open that template on the hardware model. This does not create a new template.
- If no template matches and your role can create hardware models, the footer shows Configure a PCR Template. Select it to copy the node’s reported PCR values into memory and open the hardware model’s Attestation tab. A banner on the Attestation tab offers to pre-fill a new template with the copied values. Select the link in the banner to open the create dialog prepopulated with the copied PCR values and reported EVE-OS version, then complete and save the template using the steps in Manage PCR Templates.
Details Tab
Use Details for identity, ownership, hardware, software, and lifecycle metadata. The page groups data into:
Copy controls appear on many values so you can use IDs and names in tickets, logs, or API calls.
CPU placement
The Details tab also includes a CPU placement card. Use it to check whether the node can place application instances on specific CPUs, how much CPU capacity is left in each pool, and which cores are already taken. Check this card before you deploy an application instance that uses a Dedicated or Isolated CPU policy. Hover over any label in the card to open a tooltip that explains the field. The card summary shows:
If no CPUs are free outside the ones reserved for EVE-OS, the card warns that the node is fully booked. Host processes, EVE-OS services, and every shared app then share the reserved set.
If the node status includes no CPU placement data at all, the card shows CPU placement data unavailable instead.
Expand Technical details to see:
- CPU topology: the CPU model, SMT (On or Off), the number of NUMA nodes and sockets, and every logical CPU ID the node reports. CPU IDs are not guaranteed to be contiguous or to start at zero.
- CPU allocation: a core map that groups logical CPUs by socket and NUMA node (for example, Socket 0 · NUMA 0). Each physical core appears as a box labeled Core N that contains its logical CPU IDs. Color shows the pool that owns each CPU (Housekeeping, Dedicated, Isolated, or Not reported when the CPU is not listed in any pool). Fill shows allocation. A filled cell with a dot is Allocated to a workload. An outlined cell is Free. Hover over a core to see its socket, core, and the state of each logical CPU. Below the map, the card lists the CPU IDs in each pool and the free CPU IDs in the Dedicated and Isolated pools.
- Kernel isolation: the Isolated CPU IDs and Tickless CPU IDs (
nohz_full) reported by the running kernel.
Optimize CPU placement
When the node flags application instances for repacking, a CPU placement can be improved banner appears above the CPU placement card. Repacking restarts the flagged application instances so the node can place their CPUs more efficiently. The banner lists each flagged application instance. Instances that the node only advises repacking are marked advised. To repack the flagged application instances:- Confirm you have update permission for edge nodes in the node’s project. The Optimize CPU placement button is hidden if you do not. It is also hidden for archived nodes.
- Select Refresh placement status to load the latest list from the node.
- Select Optimize CPU placement. Edge Infrastructure Services fetches the current list of flagged application instances. If none are flagged, no restart is requested.
- Review the application instances listed in the Optimize CPU placement? dialog. The restart includes instances waiting for a repack and running instances that the repack moves out of the way.
- Select Restart flagged apps.
Workloads Tab
Use Workloads to see resources associated with the node. The Workloads tab includes sub-views for:- Applications
- Patch Envelopes
- Virtual Networks
- Volumes
Adapters Tab
Use Adapters to understand how the node connects to networks and attached devices. The Adapters tab includes:- NICs
- VLANs
- LAGs
- IO Adapters
- Topology
Storage Tab
Use Storage to inspect physical storage for the node. This is different from the Volumes sub-view in Workloads:- Storage focuses on node storage devices and health.
- Volumes focuses on workload storage resources associated with Applications.
EVE-OS History
The node detail page does not include an EVE-OS History tab. To review the EVE-OS base-image publish and activate events recorded for a node, open Infrastructure > Operations > Release Manager, select the History tab, and select the node. See Release Manager. To change the EVE-OS version running on a node, see Update EVE-OS on Nodes.Configuration Overlay
You can open the configuration overlay from the node list or from the detail page. From the list:- Open Infrastructure > Fleet > Nodes.
- Hover over the row of the node you want to configure. A Configure (gear) icon appears on the right side of the row.
- Click the Configure icon. The configuration overlay opens over the list.
- General Settings > Details. Edit the node’s identity and ownership metadata, including its Title, Description, Project, Tags, Asset ID, Asset Location, and hardware Model. When the selected project is a Deployment project, this pane also shows a required Deployment Tag field. The tag assigns the node to one of that project’s deployments, and the node then receives the app, network, volume, and node policies attached to the deployment whose tag matches. Changing the Project field clears the tag you already selected, because that tag belonged to the previous project’s deployment list, so you must choose a new one before you can save. If the selected project holds no deployment records, the field reads
No deployments configured for this projectinstead of offering a list. The field is hidden for Standard and Azure IoT projects, which do not use deployment tags. See Create a Project and the Update policies on a Deployment project section of Manage Projects for how deployment records and their tags are defined. - General Settings > Administration
- Adapters > NICs
- Adapters > VLANs
- Adapters > LAGs
- Adapters > IO Adapters
- Edge View. This section appears only when Edge View is enabled for the node’s project. Use it to review the Edge View policy status and configure per-node access settings and session defaults, including the Access EVE-OS toggle, cloud session restriction, Override Access Policies toggle, and Access Edge App Instances toggle, as well as session time limits, connection limits, and the dispatcher URL. See Configure Edge View with the GUI and the Edge View Policy section of Configure Project Policies.
Verify the Result
After using the detail page:- Confirm the expected run state is shown in the Status ribbon. Confirm the admin state sub-label under Status matches the configured lifecycle state, or check the Details tab for the full Admin state value.
- Confirm the correct project and hardware model are shown.
- Check Workloads before risky actions.
- Check Configuration Status after configuration changes.
- Check Adapters and Storage if Applications cannot connect or start.
Next Steps
Node Status and Health
Interpret run state, admin state, and health signals for this node.
Configure Node Adapters
Configure NICs, VLANs, LAGs, and IO adapters on the node.
Manage Node Lifecycle
Activate, deactivate, reboot, off-board, and perform other lifecycle actions.
Tagging
Learn how node tags are used for identification, grouping, filtering, and fleet operations.